Imperial · ELEC70076 · Electrical and Electronic Engineering
ELEC70076 Sustainable Electrical Systems: exam practice questions, marked
Practise for ELEC70076 Sustainable Electrical Systems at Imperial College London with 48 quick-recall questions, 24 exam-style questions and 16 first-class stretch questions, written from the module’s published description. Write an answer and get it marked against Imperial’s grade bands in about 30 seconds, with the exact sentences that lost marks and three changes to reach the next class.
Try one free, no sign-up Create a free account
Example ELEC70076 question
A coal plant has efficiency 38%, fuel cost £10/MWh(th) and fuel emissions 0.34 tCO₂/MWh(th). A CCGT has efficiency 55%, fuel cost £25/MWh(th) and fuel emissions 0.184 tCO₂/MWh(th). (a) Calculate each plant's fuel cost and emissions per MWh of electricity. [4] (b) Find the carbon price at which the two plants have equal marginal cost. [3] (c) Compare their marginal costs at £80/tCO₂. [2] (d) Comment on the policy…
Topics covered
- Context, drivers and policy
- Wind power
- Solar photovoltaics
- Hydro power and energy storage
- Low-carbon heat and heat networks
- Intermittency: capacity credit, reserve and balancing
- Distributed generation: voltage rise and losses
- Network planning, offshore transmission and smart grids
Unizy is an independent revision tool and is not affiliated with or endorsed by Imperial College London. Marks are practice estimates, not official marks.